1000KG Capacity Industrial Water Chiller System Air Cooled 415V Heating And Cooling Units
| Brand Name: | SHP |
| MOQ: | 1 set |
| Price: | $8,000.00/sets 1-4 sets |
| Payment Terms: | L/C,T/T |
| Supply Ability: | ≥1 set |
1000KG industrial water chiller system
,industrial water chiller system 380V
,415V heating and cooling units
Product Overview ——1000 KG Capacity Air Cooled Water Chiller for Industrial Cooling Efficiency
![]()
Chiller
In cleanroom engineering projects, a chiller refers to an industrial refrigeration system based on vapor compression or absorption refrigeration cycles. Its core function is to cool a secondary refrigerant (typically chilled water) to a temperature range required by processes (commonly 7–12℃), and then deliver the cooled medium to HVAC terminal equipment and high-heat-generating process devices in the cleanroom through a closed pipeline system. As a critical supporting device, it provides a stable cold source for constant temperature and humidity control of the clean environment and heat dissipation of precision equipment, ensuring the cleanroom complies with standards such as ISO 14644 and GMP, and maintaining the stability of production and laboratory processes.
Main Specification for Chiller
Cleanrooms typically require multiple, independent water systems with precise temperature control.
| System Name | Typical Supply Temp. | Primary Purpose | Critical Requirements |
| Process Cooling Water(PCW) | Medium Temp:~12℃ - 15℃ | Cools process equipment directly (ethtools,implanters,reactors) | Extreme stability:Temp.fluctuation≤±0.5℃ to ±0.1℃.Highest reliability. |
| Ultrapure Water (UPW) Chilling | Low Temp:~7℃ - 9℃ | Cools UPW polishing loops to maintain water resistivity. | High-purity materials (SUS 316L,PVDF) to prevent ionic contamination. |
| Low-Temperature Glycol Water | Chilled Fluid:~4℃ - 6℃ | Cools special process tools or controls dewpoint in dry processes. | Glycol-water mixture to prevent freezing.Precise temperature control. |
| Reheat Hot Water | High Temp:~18℃ - 21℃ | Supplies reheat coils in AHUs for precision humidity control (dehumidify & reheat). | Stable supply temperature for consistent space conditions. |
Note:A single chiller may serve one loop,or dual-temperature chillers may supply both chilled and reheat water simultaneously.
Features at a Glance
- Precise Regulation of Cleanroom Temperature and Humidity:Deliver chilled water at a constant temperature to the cleanroom HVAC system (e.g., constant temperature and humidity units, dry cooling coils) to precisely control indoor temperature (usually with an accuracy of ±0.5–2℃) and humidity (accuracy of ±2–5% RH). It prevents temperature and humidity fluctuations from damaging the clean environment, meeting the stringent environmental requirements of ISO Class 5–8 cleanrooms and standards such as GMP.
- Targeted Cooling for Process Equipment:Provide an independent process cooling loop for high-heat-generating process equipment in cleanrooms (e.g., semiconductor lithography machines, biopharmaceutical fermentation tanks, precision testing instruments). It timely removes heat generated during equipment operation, avoiding accuracy degradation, product yield reduction or experimental data deviation caused by equipment overheating.
- Ensuring Stability of Cleanroom Pressure Differential:Cooperate with the HVAC system to maintain a reasonable pressure differential gradient between the cleanroom and adjacent areas (e.g., a positive pressure of 5–20 Pa in the clean area relative to the non-clean area), preventing unpurified external air from infiltrating. Stable refrigeration output avoids pressure differential imbalance caused by system load fluctuations, ensuring that cleanliness is not compromised.
- System Energy Consumption Optimization and Energy-saving Operation:Support energy-saving modes such as variable frequency regulation and partial load operation. It dynamically adjusts cooling capacity output according to the real-time heat load of the cleanroom (e.g., changes in heat generation from personnel, equipment and fresh air) to reduce the overall energy consumption of the HVAC system. Some high-end models can be linked with waste heat recovery systems to further improve energy utilization efficiency.
- Dual Protection for Processes and Environment:Equipped with protection functions such as high-low temperature alarm, flow monitoring and fault shutdown. It issues timely warnings or shuts down when chilled water temperature or flow is abnormal, avoiding process interruption (e.g., a sharp drop in chip production yield) or cleanroom environment out of control caused by refrigeration failure. Meanwhile, the closed-loop design prevents chilled water contamination, ensuring hygiene and safety in industries such as and food.
Related Products:
Company Profile
![]()
As a leading supplier of clean room system and clean room products,SHP is an organization that prides itself both on technical expertise as well as next level customer care.SHP offers Cleanroom Solutions to meet our clients' particular requirements specialized for pharmaceutical,biotechnology and microelectronic cleanrooms.We also provide a range of Clean Room products including wall panel,door&window and a series of clean room equipment.
As an ISO 9001:2015 certified organization,we are committed to continually improving our customer service programs while meeting or exceeding your product quality criteria.With our comprehensive customer solution offerings,excellence in products,and decades of technical expertise,we are confident that SHP can match the best to your application.
Our Certification
![]()
Our Customers
![]()
Packing and Shipping
![]()
FAQ
Q1: Where is your company?
A1:Our company is located in Suzhou City, close to Shanghai. It's a 1.5-hour drive from PVG Airport.
Q2: Are you a manufacturer or a trading company? What can I buy from you?
A2: We are manufacturers. We focus on cleanroom projects, air showers, FFUs, through boxes, dosing rooms, laminar flow hoods and benches, AHUs, and sealed doors and Windows.
Q3:When is your delivery time?
A3: If your cleanroom project includes AHU, the delivery time is 35 days. If you purchase goods without an AHU, the delivery time is 10 days.
Q4: How long is your warranty period? What kind of after-sales service can you offer?
A4: Our warranty period is two years after the completion of the project. During the warranty period, if there are any problems, we will replace it. If you can't handle it, we will send an engineer to solve it for free.
Q5:Can you conduct cleanroom validation?
A5: Yes, we can offer documentaries of DQ, IQ, OQ and PQ. Still fat & Sitting. Product operation manual, maintenance guide and a complete set of cleanroom drawings.
Q6:What are your advantages?
A6: We have a complete technical team consisting of 12 senior cleanroom and HVAC engineers to provide you with technical support. We have completed over 2,100 cleanroom projects in China and overseas. Such as Japan, Indonesia, Thailand, Bangladesh, India, North Macedonia, Saudi Arabia, Yemen, Russia, Moldova, Switzerland, Norway, the United Kingdom, Spain, France, Belgium, Kuwait, Tunisia, Mauritius, Sri Lanka, Mongolia, Philippines, Nepal, Sudan, Somaliland, Australia, New Zealand, Canada, Algeria, Egypt, Singapore, and the United States.