products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
HVAC System
Created with Pixso.

Clean Room Axial Fan 2000 - 70000m3/H Dx AHU Unit Air Handlers Hvac Custom

Clean Room Axial Fan 2000 - 70000m3/H Dx AHU Unit Air Handlers Hvac Custom

Brand Name: SHP
Model Number: Customized
MOQ: 1 set
Price: $6,000.00/sets 1-4 sets
Payment Terms: L/C,T/T
Supply Ability: ≥1 set
Detail Information
Place of Origin:
Jiangsu, China
Certification:
CE,ISO
Product Name:
Air Handling Unit AHU
Applicable Industries:
Manufacturing Plant
Type:
Air Cooled Heat Exchanger Tower
Warranty:
1 Year
Dimension(L*W*H):
Custom
Key Selling Points:
Automatic
Core Components:
Motor
Application:
Lab
Function:
Cooling\Heating
Refrigerant:
R134a
Keyword:
Cooling Air-cooled AHU Ducted
Packaging Details:
Wooden Case, Galvanized Steel Pallet, Plastic Film
Supply Ability:
≥1 set
Highlight:

Clean Room Axial Fan 2000m3/H

,

ahu unit 70000m3/H

,

air handlers hvac custom

Product Description

Product Overview  ——2000-70000m³/h Axial Fan Clean Room Dx Air Handling Unit AHU for Capacity HVAC System


Clean Room Axial Fan 2000 - 70000m3/H  Dx AHU Unit Air Handlers Hvac Custom 0

Modular Air Handing Unit

A Cleanroom AHU is a specialized environmental control system engineered to maintain the exacting conditions of a cleanroom. It achieves this through three critical functions: delivering air at a defined cleanliness standard (such as ISO 14644), precisely regulating temperature and humidity, and sustaining specified pressure gradients between areas. This integrated management provides reliable defense against airborne contaminants for processes requiring stringent purity.

Key Characteristics&Core Functions


  • Exceptional Air Filtration
    • Multi-Stage System: Pre-filters (G4/F5) → Medium-efficiency (F7/F8) → Terminal HEPA/ULPA (>99.99% @ 0.3/0.12 µm).

    • Performance Monitoring: Differential pressure sensors track filter loading for predictive maintenance.

  • Stringent Airflow & Pressure Control
    • High Airflow: Delivers very high air change rates for rapid contaminant dilution.

    • Advanced Control: Employs CAV/VAV valves and VFD fans for dynamic air balance.

    • Pressure Cascades: Maintains defined pressure gradients (e.g., +15 Pa, +10 Pa) to enforce unidirectional airflow and zone isolation.

  • Precise Temperature & Humidity Control
    • Tight Tolerances: Maintains stability within narrow bands (e.g., ±0.5°C, ±5% RH).

    • Deep Conditioning: Uses deep cooling/desiccant dehumidification and clean-steam humidification.

    • Reheat Requirement: Essential for temperature correction post-dehumidification; a major energy consumer.

  •  Superior Construction & Hygiene
    • Airtight Design: Prevents infiltration of untreated air.

    • Sanitary Interiors: Smooth, crevice-free, corrosion-resistant materials (e.g., stainless steel).

    • Dry Design: Sloped condensate pans ensure complete drainage to prevent microbial growth.

  • Energy Efficiency Focus
    • Heat Recovery: Incorporates enthalpy wheels or plate heat exchangers to reduce cooling/heating loads by preconditioning outside air, lowering operational costs.

Main Components&Functional Sections


 

Clean Room Axial Fan 2000 - 70000m3/H  Dx AHU Unit Air Handlers Hvac Custom 1  Clean Room Axial Fan 2000 - 70000m3/H  Dx AHU Unit Air Handlers Hvac Custom 2  Clean Room Axial Fan 2000 - 70000m3/H  Dx AHU Unit Air Handlers Hvac Custom 3  Clean Room Axial Fan 2000 - 70000m3/H  Dx AHU Unit Air Handlers Hvac Custom 4

    1. Mixing Box Section

      • Function: To mix outdoor fresh air (Outside Air) with recirculated indoor air (Return Air) in a controlled ratio to maintain indoor air quality and energy efficiency.

      • Key ComponentsMotorized dampers for outside, return, and exhaust air, often interlocked for proper pressure control.

    2. Filtration Section

      • Function: To remove airborne particulates (dust, pollen, microbes).

      • Filter Types:

        • Pre-filters (G3-G4): Protect downstream coils and components.

        • Medium-efficiency filters (F5-F8): Used in offices, hospitals, and general commercial spaces.

        • High-efficiency filters (HEPA, ULPA): Used in cleanrooms, operating theaters, and critical environments.

    3. Thermal Conditioning Section

      • Function: The core for controlling air temperature and moisture.

      • Key Components:

        • Cooling Coil: Uses chilled water (e.g., 6°C supply, 12°C return) or direct-expansion refrigerant to cool and dehumidify air.

        • Heating Coil: Uses hot water, steam, or electric heating elements to heat air.

        • Humidifier: Adds moisture. Common types: Dry steam injectorsadiabatic humidifiers (e.g., high-pressure mist), and electrode/ resistive steam humidifiers.

    4. Fan Section

      • Function: Provides the mechanical energy to move air through the unit and the entire duct system. It is the "heart" of the AHU.

      • Key TypesCentrifugal fans (forward or backward curved).

      • ConfigurationDraw-through (fan after coils, preferred for even air distribution and coil drainage) or blow-through (fan before coils).

      • Control: Almost always equipped with a Variable Frequency Drive (VFD) for variable airflow and energy savings.

    5. Auxiliary Sections

      • Sound Attenuators: Lined sections or silencers to reduce fan and airflow noise.

      • Heat Recovery Section: Devices like enthalpy wheelsplate heat exchangers, or run-around coils to recover energy from exhaust air and precondition incoming outside air, significantly improving efficiency.

      • Plenum / Flow Straightener: Ensures uniform airflow across filters and coils.

Related Products


Clean Room Axial Fan 2000 - 70000m3/H  Dx AHU Unit Air Handlers Hvac Custom 5

Company Profile


 

Clean Room Axial Fan 2000 - 70000m3/H  Dx AHU Unit Air Handlers Hvac Custom 6

As a leading supplier of clean room system and clean room products,SHP is an organization that prides itself both on technical expertise as well as next level customer care.SHP offers Cleanroom Solutions to meet our clients' particular requirements specialized for pharmaceutical,biotechnology and microelectronic cleanrooms.We also provide a range of Clean Room products including wall panel,door&window and a series of clean room equipment.

 

As an ISO 9001:2015 certified organization,we are committed to continually improving our customer service programs while meeting or exceeding your product quality criteria.With our comprehensive customer solution offerings,excellence in products,and decades of technical expertise,we are confident that SHP can match the best to your application.

 

Our Certification


Clean Room Axial Fan 2000 - 70000m3/H  Dx AHU Unit Air Handlers Hvac Custom 7

Customer Photos


Clean Room Axial Fan 2000 - 70000m3/H  Dx AHU Unit Air Handlers Hvac Custom 8

FAQ


Q1: Where is your company?

A1:Our company is located in Suzhou City, close to Shanghai. It's a 1.5-hour drive from PVG Airport.


Q2: Are you a manufacturer or a trading company? What can I buy from you?
A2: We are manufacturers. We focus on cleanroom projects, air showers, FFUs, through boxes, dosing rooms, laminar flow hoods and benches, AHUs, and sealed doors and Windows. 


Q3:When is your delivery time? 
A3: If your cleanroom project includes AHU, the delivery time is 35 days. If you purchase goods without an AHU, the delivery time is 10 days. 


Q4: How long is your warranty period? What kind of after-sales service can you offer?
A4: Our warranty period is two years after the completion of the project. During the warranty period, if there are any problems, we will replace it. If you can't handle it, we will send an engineer to solve it for free.


Q5:Can you conduct cleanroom validation? 
A5: Yes, we can offer documentaries of DQ, IQ, OQ and PQ. Still fat & Sitting. Product operation manual, maintenance guide and a complete set of cleanroom drawings. 


Q6:What are your advantages?
A6: We have a complete technical team consisting of 12 senior cleanroom and HVAC engineers to provide you with technical support. We have completed over 2,100 cleanroom projects in China and overseas. Such as Japan, Indonesia, Thailand, Bangladesh, India, North Macedonia, Saudi Arabia, Yemen, Russia, Moldova, Switzerland, Norway, the United Kingdom, Spain, France, Belgium, Kuwait, Tunisia, Mauritius, Sri Lanka, Mongolia, Philippines, Nepal, Sudan, Somaliland, Australia, New Zealand, Canada, Algeria, Egypt, Singapore, and the United States.